AVe · Consulting and Construction

Structural condition assessments, seismic vulnerability and strengthening

Understanding existing structures to make informed intervention decisions.

National Police General Directorate
Reference project · National Police General Directorate

Assessment before intervention

A crack, leak or corroded area may indicate deterioration, but appearance alone cannot establish a building's safety. Structural condition assessment investigates the origin, extent and consequences of damage. We distinguish finish defects from issues that may affect load-bearing components and prioritize the necessary checks.

Seismic vulnerability assessment examines how an existing structure could respond to the seismic actions required by the applicable framework. It is different from a damage survey: a building with no visible cracks may still require assessment because of its configuration, age, materials or changes in use.

From inspection to the structural model

We review drawings and records, survey the structure and its geometry, and document observed damage. We specify investigations and destructive or nondestructive tests as appropriate to characterize materials and check the available information. The investigation program is adapted to the structure and access conditions.

Using that information, we develop models to evaluate load capacity and response to gravity and seismic actions under NSR-10 and its applicable provisions for existing buildings. We explain assumptions, limitations and findings: results depend on the quality of information and the checks performed.

Strengthening solutions

When the assessment identifies intervention needs, we study options to improve strength, stiffness, stability or continuity. Depending on the analysis, these may include strengthening members, introducing new load-resisting components, or modifying connections and foundations.

We compare alternatives based on structural effects, compatibility with the building, available space and construction sequence. In occupied industrial or institutional facilities, we coordinate inspections and interventions with operations teams to reduce disruption and comply with their protocols.

Results that support decisions

The scope may include a condition assessment report, test results, seismic vulnerability and load capacity evaluations, prioritized recommendations, calculations and strengthening drawings. We explain what was found, why it matters and what actions are proposed so owners and facility managers can plan their investment.

Strengthening does not eliminate every risk or replace maintenance. The solution must be built according to the design and supported by appropriate inspections and conservation measures.

When should you request an assessment?

When there is damage, corrosion, a change of use, an extension, new equipment or loading, or uncertainty about an existing building. An initial review establishes the investigation required.

Technical references:NSR-10 Regulations: Decree 926 of 2010 · Amendments: Decree 1401 of 2023

Applied experience

Reference projects

Alpina · Líquida 2

Alpina · Líquida 2

Structural condition assessment, seismic vulnerability studies and structural strengthening

Sopó, Cundinamarca, Colombia · 4,188 m² · Fermented Products, Desserts and Fats sector

Client: Alpina Productos Alimenticios S.A. BIC

View project

Let’s discuss what your project needs.

Tell us the location, intended use and current stage. We will define the technical scope and information needed to get started.

Request information